Why DKD-calibration certificates ?
Reply:
Calibrations carried out by DKD laboratories allow the user to trust in the reliability of measurement results. They increase the customers' confidence and competitiveness on the national and international markets. They also serve as a metrological basis for the control of measurement and test equipment within the framework of quality assurance measures.

The German calibration service (Deutscher Kalibrierdienst DKD) secures the following points:

1. Securing quality, accuracy and reliability in the industry
2. The DKD-calibration documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI)
3. regular control of the PTB
4. international validity
5. obligatory also by court
6. calibration with valid guidelines (from the PTB)
Top
Humidity
How to refresh an hair hygrometer ?
Reply:
To avoid the dry up, you have to refresh the hair hygrometer in regular intervals. For this the hair has to be saturated with destillated water at 20°C ambient temperature. After about one hour you get a measurement value of 98%rH. The most instruments are adjustable with an adjustment-screw.
Top
OPUS 10
The data stored in the OPUS 10 cannot be read out by the software SmartGraph2 (up to version 2.1.7)
Reply:
This mainly occurs on laptops equipped with windows 2000, windows XP or windows 98.

solution: for reading the Datalogger, the Energy Saver on the Desktop should be changed

Carry out as follows (Windows 2000):
1. Select "properties" by rightclicking anywhere on the desktop
2. Select the "screen saver " tab
3. Click on the button "settings"
4. Select the operating mode "desktop"
5. Confirm this modification by pressing "OK"
6. Confirm again by pressing "OK"

If an error message occurs while carrying through this modification, please contact your administrator.

Top
OPUS 10
Block-Header error
Reply:
Delete memory via SmartGraph2 and synchronize clock.
Top
OPUS 10
Probe error after battery change (OPUS 10 with two external temperature probes)
Reply:
1. Remove blue sensor module.
2. After appearing "FAIL" on the display, plug the sensor module back again.
3. After appearing "SENS" on the display, connect the first temperature probe to the right and the second temperature probe to the left socket within the given time of 10 seconds.
Top
OPUS 200(i)/300(i)/208
Connection Meteo Sensors
Reply:
All connections of the meteorological sensors are described in the Meteo Manual. Furthermore, the configuration via the software SmartControl is explained.

Please go to Support/Download/Manual/Manual Connection Meteo Sensors OPUS 200/300/208 (GB)
Top
OPUS 200(i)/300(i)/208
Power-supply depending on the OPUS 200/300/208 versions
Reply:
OPUS200, Ref. No. 8160.00: 12V power-supply
OPUS300, Ref. No. 8160.10: 12V power-supply
OPUS208, Ref. No. 8162.00: 12V power-supply

OPUS200(i), Ref. No. 8161.00: 24V power-supply
OPUS300(i), Ref. No. 8161.10: 24V power-supply
Top
Software
Is SmartGraph 2 executable under XP ?
Reply:
SmartGraph2 is executable starting from V2.20 under XP. The software must be installed however, as with Windows XP usual, with administrator rights.
Top
Software
Problems during the installation of SmartGraph2 OPUS10 under Windows Vista
Reply:
Has to be installed under c:/SmartGraph and not as proposed from the setup program under c:/programs/SmartGraph
Top
Software
The error message "The locale (0,1) is not supported by the current code page" appears after successful installation of SmartGraph2
Reply:
it is a Windows (Setup) problem; for assistance please go to http://support.microsoft.com
Top
Software
SmartControl Pharma ? Start-up, file opening and ending the Pharma version of Smartcontrol takes up to one minute. On the same PC, these procedures are executed quickly in non-Pharma versions.
Reply:
This error occurs on systems with more than one (virtual) processor, including Pentium 4 with hyperthreading, when Smartcontrol and the Interbase Server required for the Pharma version are running on different (virtual) processors.

Solution:
1) On Pentium 4 with hyperthreading:
Switch off hyperthreading in the computer?s Bios Setup

2) On multi-processor computers without Windows XP Service Pack 2: The Interbase Server required for the Pharma version and Smartcontrol must run on the same (virtual) CPU to prevent the error from occurring. This can be set up for each system start by means of a software tool. This tool is available on request.

3) On multi-processor computers with Windows XP Service Pack 2: No known tool at present, since the tool described under item 2 above does not function with Windows XP SP2. Use a different PC if possible.
Top
Software
Problems occuring when starting SmartGraph 1.xx after installation
Reply:
concerned versions are Smartgraph OPUS, Smartgraph Agro and Smartgraph GMA in different program versions for OPUS 1, OPUS 2, OPUS 2-GMA and HP-100.

Symptoms: After SmartGraph 1 has been successfully installed on the PC, the following error message appears when starting the program:

Exception EGPFault in
module SG_xxxx.EXE at xxxx:xxxx.
General protection failure...

Depending on the program and version, the xxxx are different. SmartGraph 1 will close after the error message has been displayed.

Help: Delete Smartgraph 1 and install it again along with the demo data.
Top